SMART GRID 智慧電網
  • SMART GRID
    • Monitoring & Control
    • Data Analytics
    • Supply Reliability
    • DER Integration
    • Security
    • Green Energy
    • Customer Empowerment & Satisfaction
  • TAIPOWER
    • Smart Grids in Taiwan
    • Featured Video
    • Research
    • Organizational Chart
    • Team
  • NEWS
Mobile nav
  • Monitoring & Control
    • Outline
    • Central Dispatch Control Center (CDCC)
    • Area Dispatch Control Center (ADCC)
    • Distribution Dispatch Control Center (DDCC)
    • ADMS
    • GEMS & DREAMS
  • Data Analytics
    • AMI Data Applications
    • Big Data Analytics
    • Renewable Energy on Data Collection and Visualized Hosting Capacity
    • Grid-related Data Analysis Projects
  • Supply Reliability
  • DER Integration
  • Security
  • Green Energy
    • Renewable Energy
    • Electric Vehicle (EV)
  • Customer Empowerment & Satisfaction
    • AMI Infrastructure
    • Website Service
    • Other APPs(such as Taipower and power is points)
    • Electricity rate plan & DR
    • Power saving service team and development of Energy Service Company
    • Customer Satisfaction

Monitoring & Control 

Area Dispatch Control Center (ADCC)

Introduction of ADCC

 

Taiwan Power Company (TPC) Area Dispatch Control System (ADCS) are currently using a hybrid of SCADA solutions across its 6 Control Centres in Taiwan. ADCS SCADA systems monitor and/or control the following substations: Extra High Voltage substations(345/161kV), Primary Substations (161/69kV), Distribution Substations(161/22/11kV) and Secondary Substations(69/11kV). Besides SCADA, ADCS also runs Volt/Var control to maintain and/or improve the power factor and regulates bus voltage in substations.

 

TPC plans to reduce the number of control systems from 6 to 5, namely New Taipei ADCS (combining Keelung and Taipei ADCS), Hsinchu ADCS, Taichung ADCS, Hsinying ADCS and Kaohsiung ADCS. Each Control System will have their respective hot backup system. State-of-the-art features such as Historical Information Server, Multisite, Reactive Power Device Control, Common Information Model, Cyber Security enforcement and development platform will also be included.

The functions of ADCS in the future are listed the following:

  1. The dynamic display for monitor and control such as Geographic Information System (GIS) is included.
  2. Provide the space that complied with IEC 61970 Common Information Model (CIM) to save historical grid operation information for mor than 10 years.
  3. The reports in tabular in-build could be modified according to the operator needs.
  4. Support SMS function that the message can be check before sending.
  5. The scheme of control in RPDC can be satisfying to the necessary for system reliability.
  6. Provide Remote backup solution to protect ADCS from server failure.
  7. The RTU apply DNP3.0 over Ethernet for communication to advance the reliability in data routing.
  8. Provide the connection between DMZ and intranet to prevent the cyber security from hacking.

Supervisory Control And Data Acquisition (SCADA) function.

The scheme of control in RPDC can be satisfying to the necessary for system reliability.

Save historical grid operation information for more than 10 years.

Next

Distribution Dispatch Control Center (DDCC)

Continue
  • ABOUT.
    • Behind the Scenes
    • Featured Video
    • News
    • Sitemap
  • LINK.
    • BSMI
    • IDB
    • Bureau of Energy
    • ITRI
    • T-REC
facebook
shareTool

Copyright © 2021 Taiwan Power Company All rights reserved

  • SMART GRID
    • Monitoring & Control
    • Data Analytics
    • Supply Reliability
    • DER Integration
    • Security
    • Green Energy
    • Customer Empowerment & Satisfaction
  • TAIPOWER
    • Smart Grids in Taiwan
    • Featured Video
    • Research
    • Organizational Chart
    • Team
  • NEWS
  • Contact Us